Mita, Dina (2021) Rancang Bangun Bilah Turbin Angin Skala Mikro Sumbu Horisontal Tipe Taper Dengan Variasi Mixed Airfoil. Undergraduate thesis, Politeknik Negeri Jember.
Text (Abstrak)
ABSTRACT.pdf - Submitted Version Available under License Creative Commons Attribution Share Alike. Download (4MB) |
|
Text (Bab 1 Pendahuluan)
BAB 1 PENDAHULUAN.pdf - Submitted Version Available under License Creative Commons Attribution Share Alike. Download (4MB) |
|
Text (Daftar Pustaka)
DAFTAR PUSTAKA.pdf - Submitted Version Available under License Creative Commons Attribution Share Alike. Download (4MB) |
|
Text (Laporan Lengkap)
H41171915_LAPORAN LENGKAP.pdf - Submitted Version Restricted to Registered users only Download (4MB) | Request a copy |
Abstract
Energy is a fundamental need in economic development. Indonesia is a country with abundant natural resources potential, especially wind energy potential. In 2019, Indonesia has wind energy potential of 60,6 GW and wind energy is not yet maximized. So a method is needed to be able to overcome this, one of which is by utilizing renewable energy through micro-scale wind turbines. Micro-scale wind turbines themselves have several advantages such as easier installation and can be adjusted to the potential wind speed in certain areas. Blades are one of the wind turbine systems that serve to convert the kinetic energy of the wind into mechanical energy. The purpose of this study was to find out the design, performance and electrical energy of NACA 4412, NACA 4415 and NACA 4418 mixed airfoil taper blades. This study used horizontal axis wind turbine number of blades 3 with a type of taper mixed airfoil designed and made using materials of mahogany wood (Swietenia macrophylla) for micro-scale wind turbines generator power capacity 500 Wp at a maximum wind speed of 12 m / s with a blade radius of 0,8 m, twist (pitch 7°) is 6,55°-15,88° and chord (0,044 m) is 0,07 m – 0,12 m using airfoil NACA 4412, NACA 4415 and NACA 4418. Bar testing is conducted for 3 days and for data retrieval time is done for 24 hours. For blade performance (Cp) was obtained at a value of 51% in TSR 5 with the acquisition of total electrical energy generated by the first day of testing of 549,57 Wh, the second day of 560,68 Wh and the third day of 375,54 Wh. Keywords: Taper Mixed Airfoil, Blade Performance, Energy
Item Type: | Thesis (Undergraduate) | ||||||
---|---|---|---|---|---|---|---|
Contributors: |
|
||||||
Uncontrolled Keywords: | Taper Mixed Airfoil, Blade Performance, Energy | ||||||
Subjects: | 410 - Rumpun Ilmu Teknik > 430 - Ilmu Keteknikan Industri > 431 - Teknik Mesin (dan Ilmu Permesinan Lain) | ||||||
Divisions: | Jurusan Teknik > Prodi D4 Teknik Energi Terbarukan > Tugas Akhir | ||||||
Depositing User: | Dina Mita | ||||||
Date Deposited: | 14 Oct 2021 04:19 | ||||||
Last Modified: | 14 Oct 2021 04:20 | ||||||
URI: | https://sipora.polije.ac.id/id/eprint/7277 |
Actions (login required)
View Item |