Pengaruh Diameter Pipa Udara Dan Jumlah Katup Buang Terhadap Variasi Aliran Pada Pompa Hidram Model T

Maulana, Ahmad Dzaky (2020) Pengaruh Diameter Pipa Udara Dan Jumlah Katup Buang Terhadap Variasi Aliran Pada Pompa Hidram Model T. Undergraduate thesis, Politeknik Negeri Jember.

[img] Text (Abstract)
08. HALAMAN ABSTRAC.pdf - Submitted Version
Available under License Creative Commons Attribution Share Alike.

Download (25kB)
[img] Text (Bab 1 Pendahuluan)
15. BAB 1. PENDAHULUAN.pdf - Submitted Version
Available under License Creative Commons Attribution Share Alike.

Download (36kB)
[img] Text (Daftar Pustaka)
20. DAFTAR PUSTAKA.pdf - Submitted Version
Available under License Creative Commons Attribution Share Alike.

Download (64kB)
[img] Text (H41160189_LAPORAN LENGKAP)
H41160189_LAPORAN LENGKAP.pdf - Submitted Version
Restricted to Repository staff only

Download (1MB) | Request a copy

Abstract

Water is an important requirement for humans. However, in certaint areas it is difficult to get it, especially people who live in high places where the water source is below. In this case the use of a hydraulic ram pump can help the community. Hidraulic ram pump currently use one waste valve.The metod used experimental method that increases the number of waste valves and varies the diameter of the air pipe. The result show that the number of waste valves has an influence on the performance of the hydram pump. Output discharge between 1 valve hydramp pump with 3 inch and 4 inch diameter variation of air pipe, to the 2 valve hydram pump series with variations in the diameter of the air pipe 3 inches and 4 inches there was an in crease of 33% and 34% , between 2 waste valves in series with variations in the diameter of air pipe 3 inches and 4 inches, to a hydram pump 3 waste valves in parallel to the T model with variations in the diameter of the air pipe 3 inches and 4 inches an crease of 45% and 45% . The highest D'Aubuission efficiency on a 2 valve pump in parallel with a variation of the air pipe 3 inches and 4 inches 32.217% and 49.337%. The efficiency of 1 valve hydram pump with 3 inch and 4 inch air pipe variations is 33.572%, and 31.807%. At the efficiency of the 3 valve hydram pump in parallel model T with variations of the air pipe 3 inches and 4 inches 27.714%, and 32.700%.

Item Type: Thesis (Undergraduate)
Contributors:
ContributionContributorsNIDN/NIDK
Thesis advisorNuruddin, MochammadNIDN0011117603
Uncontrolled Keywords: Pompa Hidram, Air, Katup
Subjects: 410 - Rumpun Ilmu Teknik > 430 - Ilmu Keteknikan Industri > 443 - Teknik Enerji
Divisions: Jurusan Teknik > Prodi D4 Teknik Energi Terbarukan > Tugas Akhir