Analisis Pengaruh Soiling Terhadap Performance Ratio Pada Panel Surya

Meisyah, Ines Amelia (2026) Analisis Pengaruh Soiling Terhadap Performance Ratio Pada Panel Surya. Undergraduate thesis, Politeknik Negeri Jember.

[img] Text (Abstract)
Abstract.pdf - Submitted Version
Available under License Creative Commons Attribution Share Alike.

Download (229kB)
[img] Text (Bab 1 Pendahuluan)
Bab 1 Pendahuluan.pdf - Submitted Version
Available under License Creative Commons Attribution Share Alike.

Download (221kB)
[img] Text (Daftar Pustaka)
Daftar Pustaka.pdf - Submitted Version
Available under License Creative Commons Attribution Share Alike.

Download (217kB)
[img] Text (Laporan Lengkap)
Laporan Lengkap.pdf - Submitted Version
Restricted to Registered users only

Download (3MB) | Request a copy

Abstract

The utilization of Solar Power Plants (PLTS) continues to increase; however, the performance of solar panels can decline due to soiling, which refers to the accumulation of dust on the panel surface that reduces the solar radiation received by the panels and affects the Performance Ratio (PR). This study aims to analyze the influence of environmental factors on soiling levels, determine the effect of dust mass on PR values, and develop recommendations for panel cleaning schedules based on data obtained from the soiling monitoring system. The experiment was conducted on a laboratory-scale DC Solar Power Plant using a 50 Wp solar panel with dust mass variations of 0, 5, 10, and 15 grams. The actual PR values obtained from measurements were compared with the PR value obtained from simulations using PVsyst. The results showed that dust mass was the most dominant factor contributing to the increase in soiling levels, while changes in ambient temperature, humidity, and wind speed during the experiment were relatively small. In addition, panel temperature also contributed to changes in soiling levels due to its influence on the panel surface conditions and the adhesion of dust particles. Increasing the dust mass from 0 to 15 grams resulted in a decrease in the actual PR value from 58.09% to 43.56%, while the PR value obtained from the PVsyst simulation was 38.27%. Based on the economic soiling threshold of 7%, solar panel cleaning is recommended when the soiling level approaches or exceeds this threshold to maintain optimal PLTS performance.

Item Type: Thesis (Undergraduate)
Contributors:
ContributionContributorsNIDN/NIDK
Thesis advisorFaizin, S.Si., M.Si., NurNIDN0018058903
Uncontrolled Keywords: Performance Ratio, PLTS, soiling, PVSyst, sistem pemantauan
Subjects: 410 - Rumpun Ilmu Teknik > 450 - Teknik Elektro dan Informatika > 451 - Teknik Elektro
410 - Rumpun Ilmu Teknik > 450 - Teknik Elektro dan Informatika > 454 - Teknik Elektronika
Divisions: Jurusan Teknik > Prodi D4 Teknik Energi Terbarukan > Tugas Akhir
Depositing User: Ines Amelia Meisyah
Date Deposited: 03 Aug 2026 00:41
Last Modified: 03 Aug 2026 00:41
URI: https://sipora.polije.ac.id/id/eprint/58963

Actions (login required)