Analisis Kinerja Teknologi Mikrohidro Di Pt Luis Jaya Kecamatan Songgon Kabupaten Banyuwangi

Putra, Mico Syah (2026) Analisis Kinerja Teknologi Mikrohidro Di Pt Luis Jaya Kecamatan Songgon Kabupaten Banyuwangi. Undergraduate thesis, Politeknik Negeri Jember.

[img] Text (Abstract)
Abstract.pdf - Submitted Version
Available under License Creative Commons Attribution Share Alike.

Download (192kB)
[img] Text (Bab 1 Pendahuluan)
Bab 1 Pendahuluan.pdf - Submitted Version
Available under License Creative Commons Attribution Share Alike.

Download (144kB)
[img] Text (Daftar Pustaka)
Daftar Pustaka.pdf - Submitted Version
Available under License Creative Commons Attribution Share Alike.

Download (165kB)
[img] Text (Laporan Lengkap)
Laporan Lengkap.pdf - Submitted Version
Restricted to Registered users only

Download (2MB) | Request a copy

Abstract

This study aims to analyze the characteristics of water resource potential and evaluate the operational technical performance, electrical power output, and efficiency of the Micro-Hydro Power Plant (MHPP) at PT Luis Jaya, Wisata Desaku area, Songgon District, Banyuwangi Regency. The research method involved collecting primary hydrological and electrical data during a five-day testing period (April 15–19, 2026). Field observations revealed that the water flow velocity in the settling basin channel ranged from 0.100 m/s to 0.267 m/s. Multi- sector water allocation analysis confirmed that the MHPP operation does not disrupt local agricultural irrigation, which maintains a flow of 0.0572 m³/s to 0.06864 m³/s. On average, the MHPP operates at a water flow rate of 0.0764 m³/s, generator voltage of 129.2 Volts, and load current of 3.63 Amperes, generating a continuous average electrical power output of 505.0 Watts with an integrated system efficiency of 22.98%. The highest conversion efficiency reached 21.80% (505.0 Watts output) under a medium-low flow of 0.0580 m³/s, operating near the Best Efficiency Point (BEP) of the crossflow turbine. Conversely, at a peak flow of 0.0980 m³/s, efficiency dropped to a minimum of 14.19% due to flow turbulence triggering high minor head losses. To maintain optimal performance, stable regulation of the intake gate within the flow range of 0.0580 m³/s to 0.0700 m³/s is highly recommended.

Item Type: Thesis (Undergraduate)
Contributors:
ContributionContributorsNIDN/NIDK
UNSPECIFIEDHananto, YuliNIDN0022077701
Uncontrolled Keywords: PLTMH, Analisis Kinerja, Debit Air, Efisiensi Sistem, Turbin Crossflow
Subjects: 100 - Rumpun Matematika dan Ilmu Pengetahuan Alam (MIPA) > 120 - Matematika > 122 - Statistik
410 - Rumpun Ilmu Teknik > 430 - Ilmu Keteknikan Industri > 443 - Teknik Enerji
Divisions: Jurusan Teknik > Prodi D4 Teknik Energi Terbarukan > Tugas Akhir
Depositing User: Mico Syah Putra
Date Deposited: 21 Jul 2026 00:47
Last Modified: 21 Jul 2026 00:48
URI: https://sipora.polije.ac.id/id/eprint/58389

Actions (login required)

View Item View Item