Yusron, Moch (2023) Analisis Perencanaan Plts Off-Grid Pada Teknologi Venturi Finebubble Portable Buoy Di Tambak Udang Karangrejo Banyuwangi Menggunakan Pv Syst 7.2.4. Undergraduate thesis, Politeknik Negeri Jember.
Text (Abstract)
Abstract.pdf - Submitted Version Available under License Creative Commons Attribution Share Alike. Download (1MB) |
|
Text (Bab 1 Pendahuluan)
Bab 1. Pendahuluan.pdf - Submitted Version Available under License Creative Commons Attribution Share Alike. Download (1MB) |
|
Text (Daftar Pustaka)
Daftar Pustaka.pdf - Submitted Version Available under License Creative Commons Attribution Share Alike. Download (1MB) |
|
Text (H41191210_Laporan Lengkap)
H41191210_Laporan Lengkap.pdf Restricted to Registered users only Download (1MB) | Request a copy |
Abstract
Indonesia is a tropical country with a significant potential for solar energy, particularly in regions that are exposed to intense sunlight such as Java, Bali, and Nusa Tenggara. Photovoltaic Solar Power Systems (PLTS) are renewable energy systems that convert solar energy into electricity using semiconductor photovoltaic modules. The location for the off-grid PLTS planning is in Karangrejo Village, Banyuwangi, with coordinates 8.25°S and 114.38°E, which has an average solar irradiation potential of 5.78 kWh/m2/day obtained from PVsyst 7.2.4 software. The objective of this research is to analyze the amount of energy that can be generated in the off-grid PLTS planning. The analysis involves a combination of theoretical calculations and simulations using PVsyst software. The components of the PLTS include a DXM5-36P-100Wp solar module, a PWM Power 20A SCC unit, and a 12V 65Ah NARADA battery. Based on mathematical calculations, the off-grid PLTS at that location can generate an annual energy output of 147.679 kWh/year, while the simulated energy output using PVsyst 7.2.4 software is 133.72 kWh/year. The test results of the off-grid PLTS conducted over a one-month period yielded an energy output of 10.042 kWh, whereas the simulation for the same data collection period resulted in an energy output of 12.09 kWh. Hence, there is a difference of 2.042 kWh between the energy generated from the test and the simulation.
Item Type: | Thesis (Undergraduate) | ||||||
---|---|---|---|---|---|---|---|
Contributors: |
|
||||||
Uncontrolled Keywords: | Energy, Off-grid PLTS, PV syst 7.2.4 | ||||||
Subjects: | 410 - Rumpun Ilmu Teknik > 430 - Ilmu Keteknikan Industri > 443 - Teknik Enerji | ||||||
Divisions: | Jurusan Teknik > Prodi D4 Teknik Energi Terbarukan > Tugas Akhir | ||||||
Depositing User: | Moch Yusron | ||||||
Date Deposited: | 11 Jul 2023 03:19 | ||||||
Last Modified: | 11 Jul 2023 03:19 | ||||||
URI: | https://sipora.polije.ac.id/id/eprint/24739 |