Analisis Termodinamika Dan Optimasi Sistem Pembangkit Listrik Tenaga Panas Bumi Single-Flash Steam Cycle Di Pt. Geo Dipa Energi (Persero) Unit Dieng

Bahthiyar, Muhamad Aries (2019) Analisis Termodinamika Dan Optimasi Sistem Pembangkit Listrik Tenaga Panas Bumi Single-Flash Steam Cycle Di Pt. Geo Dipa Energi (Persero) Unit Dieng. Undergraduate thesis, Politeknik Negeri Jember.

[img] Text (Abstrak)
08. ABSTRACT.pdf - Submitted Version
Available under License Creative Commons Attribution Share Alike.

Download (29kB)
[img] Text (Bab 1 Pendahuluan)
15. BAB 1 PENDAHULUAN.pdf - Submitted Version
Available under License Creative Commons Attribution Share Alike.

Download (39kB)
[img] Text (Daftar Pustaka)
20. DAFTAR PUSTAKA.pdf - Submitted Version
Available under License Creative Commons Attribution Share Alike.

Download (33kB)
[img] Text (Laporan Lengkap)
22. H41150858 LAPORAN LENGKAP SKRIPSI.pdf
Restricted to Registered users only

Download (1MB)

Abstract

Thermodynamic analysis and optimization of single-flash steam cycle geothermal power plant in PT. Geo Dipa Energi (Persero) Unit Dieng was done based on energy and exergy analysis. Energy and exergy stream calculated on each state and main component such as separator, scrubber, demister, turbine, main condenser, intercondenser, aftercooler, cooling tower, and flasher. Energy analysis gave an information about the amount of energy stream on each component. Afterwards, exergy analysis gave an information about exergetic efficiency and irreversibility of each component. Besides, the exergy analysis was done with environmental temperature variation or dead state. Optimization was done on each component which has the biggest irreversibility. The exergy analysis result showed that exergy stream from production well is about 106515 kW which is used for electricity production for about 40680 kW with 38,19% exergy efficiency system. The biggest irreversibility happened in turbine on 11217 kW. Exergy optimization was done on turbine as a component that have the biggest irreversibility in geothermal power plant system. Optimization was done with variation of inlet turbine pressure. The optimization result showed that the higher the inlet turbine pressure caused the turbine irreversibility increased and exergetic turbine efficiency decreased. Inlet turbine optimum pressure reached on 5,5 bar pressure with the maximum pressure changing depend on environmental temperature. Keywords: Energy, Exergy, Irreversibility, and Optimization

Item Type: Thesis (Undergraduate)
Contributors:
ContributionContributorsNIDN/NIDK
UNSPECIFIEDRudiyanto, Bayu197312212002121001
Subjects: 410 - Rumpun Ilmu Teknik > 470 - Teknologi Kebumian > 471 - Teknik Panas Bumi
Divisions: Jurusan Teknik > Prodi D4 Teknik Energi Terbarukan > Tugas Akhir
Depositing User: Usman Efendi
Date Deposited: 30 Mar 2023 02:18
Last Modified: 30 Mar 2023 02:18
URI: https://sipora.polije.ac.id/id/eprint/21620

Actions (login required)

View Item View Item